1
INSTALLATION MANUAL
AND USER’S GUIDE
Revision 5.8
Patent Pending
www.ActiveForever.com
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - AND USER’S GUIDE

1 INSTALLATION MANUAL AND USER’S GUIDE Revision 5.8 Patent Pending www.ActiveForever.com

Seite 2

10 !!! WARNING !!! THE POWER ADAPTER MUST BE SCREWED DOWN TO PREVENT THE ADAPTER FROM BEING ACCIDENTALLY UNPLUGGED. THIS ADAPTER IS HEAVY AND CAN

Seite 3 - INTRODUCTION

11 The Autocloser must be mounted in a position with the infrared sensors aimed straight to-ward the reflector (Fig. 3-2). In order to accomplish th

Seite 4

12 Determine your mounting location by holding the Autocloser unit against the garage door opener power head assembly with the infrared sensor facing

Seite 5

13 5. Wire the Autocloser to the garage door opener. Read your garage door opener manual to determine where the wall button terminals are located on

Seite 6 - PARTS IDENTIFICATION

14 6. Wire the disable button to the Autocloser. Locate the disable button next to the ga-rage door opener wall button. Attach one end of each wire,

Seite 7 - J brace, reflector, bolt

15 7. Test the Autocloser system. Plug in the garage door opener. A. Switch the system to on. Close then reopen the garage door. As soon as the doo

Seite 8 - Fig. 1-3

16 !!!WARNIN STAY AWAY FROM THE DOOR WHILE IT IS CLOSING - THE GA-RAGE DOOR CAN CAUSE SEVERE INJURY!!! When the timer finishes it’s count, the syst

Seite 9

17 Fig. 8INSTALLATION OF OPTIONAL I-opener subsystem HARDWARE The I-opener subsystem can be installed anytime after the Autocloser-GA has been in-sta

Seite 10 - Infrared

18 10. Drill holes for the I-Opener terminal plate. Position the back of the terminal in the hole. Mark the terminal plate holes

Seite 11 - Fig. 3-3

19 12. Wire the I-Opener terminal to the Autocloser. Run the wire from the I-Opener terminal to the Autocloser unit attaching the wire to the wall

Seite 12 - Fig. 4-1

2 Autocloser is designed and manufactured by NOTE: This equipment has been tested and found to comply with the limits for a Clas

Seite 13

20 13. Insure that nobody is standing under the garage door. Plug the garage door opener back into its 110 Volt household receptacle. 14. Prog

Seite 14 - Fig. 6-1

21 OPERATION AND PROGRAMMING The Autocloser system is ready to operate straight out of the box. Once installed, the unit will automatically close yo

Seite 15

22 TIP- The auto close cancel feature can be used whenever the Autocloser begins its continuous warning beeps. 4) Set the auto close delay time - T

Seite 16

23 The unit does not beep or beeps intermit-tently when aligning the reflector while in setup mode STEP 1 1) Make sure the switch is

Seite 17 - HARDWARE

24 STEP 4 ?Press and release the Disable button while the unit is on. Does the unit beep twice?  No- Go to Step 1 and re-align the refl

Seite 18

25 7) Unit begins to beep?  Yes- Unit is working. Fol-low all installation steps.  No– please contact Xcel-tronix, Inc. for possible warranty se

Seite 19 - Fig. 12-1

26 2) Unit beeps three times?  Yes- Unit has been pro-grammed with this I-button key code. Go to Step 9  No- Go

Seite 20 - Attach white wire

28 FAQ 1. Can I have my unit professionally installed? Xceltronix, Inc. is partnering with local professional garage door insta

Seite 21 - OPERATION AND PROGRAMMING

29 6. Do I have to install the disable button? Yes, while the unit will work without the disable button installed, it is needed to re-enable the syst

Seite 22

3 INTRODUCTION Congratulations on your purchase of an Autocloser automatic garage door closer. We are certain that this little black box will give you

Seite 23 - TROUBLE SHOOTING GUIDE

4 this is intended to increase the safety of the system, these features are not intended to nor do they replace the auto reversing safety features tha

Seite 24

5 TOOLS RECOMMENDED PARTS LIST Item Description 1) 1 terminal wire 2ft. 2) 1 Disable wire 25 ft. 3) 1 Disable button 4)

Seite 25

6 PARTS IDENTIFICATION www.ActiveForever.com

Seite 26

7 INSTALLATION OF Autocloser HARDWARE RNING !!! To reduce the risk of severe injury or death: Read all instructions before installing. 1. Instal

Seite 27 -

8 1b. Attach reflective conspicuity tape to reflector plate. Peel off adhesive backing from the conspicuity tape and affix to side

Seite 28

9 2. Connect power to the Autocloser. The Autocloser uses a 110 Volt AC / DC power adapter. Attach each power wire to one of the screw terminals on

Kommentare zu diesen Handbüchern